Cover: The MAK Collection for Occupational Health and Safety

The MAK Collection for Occupational Health and Safety

German Research Foundation – Permanent Senate Commission for the Investigation of Health Hazards of Chemical Compounds in the Work Area
(MAK Commission)

ISSN 2509-2383



Phthalate – Methode zur Bestimmung von Phthalaten in der Luft am Arbeitsplatz mittels Gaschromatographie‐Massenspektrometrie (GC‐MS)

Luftanalysen-Methode

Lutz Nitschke1 (Methodenentwicklung)
Dietmar Breuer2 (Methodenprüfung)
Adela Frenzen1 (Methodenentwicklung)
Birgit Heinrich2 (Methodenprüfung)
  Ralph Hebisch3 (Leitung der Arbeitsgruppe „Luftanalysen“ der Ständigen Senatskommission zur Prüfung gesundheitsschädlicher Arbeitsstoffe, Deutsche Forschungsgemeinschaft)
  Andrea Hartwig4 (Vorsitz der Ständigen Senatskommission zur Prüfung gesundheitsschädlicher Arbeitsstoffe, Deutsche Forschungsgemeinschaft)
  MAK Commission5

1 Bayerisches Landesamt für Gesundheit und Lebensmittelsicherheit (LGL), Dienstgebäude Pfarrstraße 3, 80538 München, Deutschland
2 Institut für Arbeitsschutz der Deutschen Gesetzlichen Unfallversicherung (IFA), Alte Heerstraße 111, 53757 Sankt Augustin, Deutschland
3 Bundesanstalt für Arbeitsschutz und Arbeitsmedizin (BAuA), Friedrich-Henkel-Weg 1–25, 44149 Dortmund, Deutschland
4 Institut für Angewandte Biowissenschaften, Abteilung Lebensmittelchemie und Toxikologie, Karlsruher Institut für Technologie (KIT), Adenauerring 20a, Geb. 50.41, 76131 Karlsruhe, Deutschland
5 Ständige Senatskommission zur Prüfung gesundheitsschädlicher Arbeitsstoffe, Deutsche Forschungsgemeinschaft, Kennedyallee 40, 53175 Bonn, Deutschland

This analytical method is a validated measurement procedure for the determination of several phthalates such as dimethyl phthalate, diethyl phthalate, diallyl phthalate, diisobutyl phthalate, dibutyl phthalate, benzyl butyl phthalate, dicyclohexyl phthalate, bis(2‐ethylhexyl) phthalate and bis(2‐propylheptyl) phthalate in workplace air. With this measure procedure airborne phthalates in the gaseous state and bound to particles are collected simultaneously. Sampling is performed by drawing a defined volume of air through a sampling system consisting of a glass fibre filter located in a GSP sampling head and an adsorption tube filled with PU foam connected downstream using a suitable pump. The flow rate is set to 1 L/min with a recommended air sample volume of 60 to 120 litres. For sample preparation the collected phthalates are desorbed from the sample carriers with 1,4‐dioxane. The sample solutions are analysed by means of gas chromatography mass spectrometry (GC‐MS). The quantitative determination is based on calibration functions obtained by means of multiple‐point calibrations. The limit of quantification for the individual phthalate lies between 0.015 and 0.096 mg/m3.


Keywords

phthalates, air monitoring, analytical method, workplace measurement, hazardous substance, gas chromatography, mass spectrometry, GC-MS, glass fibre filter, PU foam