Cover: The MAK Collection for Occupational Health and Safety

The MAK Collection for Occupational Health and Safety

Deutsche Forschungsgemeinschaft – Ständige Senatskommission zur Prüfung gesundheitsschädlicher Arbeitsstoffe (MAK-Kommission)

ISSN 2509-2383



Furan – Bestimmung von Furan in Ausatemluft mittels GC-MS/MS

Biomonitoring-Methode

Chris-Elmo Ziener1 (Methodenentwicklung)
Charleen Otto1 (Methodenentwicklung)
Otto Lorenz Contreras1 (Methodenentwicklung)
Bernd Roßbach2 (Methodenprüfung)
Kerstin Lüddens-Dämgen2 (Methodenprüfung)
  Thomas Göen3 (Leitung der Arbeitsgruppe „Analysen in biologischem Material“ der Ständigen Senatskommission zur Prüfung gesundheitsschädlicher Arbeitsstoffe, Deutsche Forschungsgemeinschaft)
  Andrea Hartwig4 (Vorsitz der Ständigen Senatskommission zur Prüfung gesundheitsschädlicher Arbeitsstoffe, Deutsche Forschungsgemeinschaft)
  MAK Commission5

1 Bundesanstalt für Arbeitsschutz und Arbeitsmedizin (BAuA), Nöldnerstraße 40/42, 10317 Berlin, Deutschland
2 Universitätsmedizin der Johannes Gutenberg-Universität Mainz, Institut für Arbeits-, Sozial- und Umweltmedizin, Obere Zahlbacher Straße 67, 55131 Mainz, Deutschland
3 Friedrich-Alexander-Universität Erlangen-Nürnberg, Institut und Poliklinik für Arbeits-, Sozial- und Umweltmedizin, Henkestraße 9–11, 91054 Erlangen, Deutschland
4 Institut für Angewandte Biowissenschaften, Abteilung Lebensmittelchemie und Toxikologie, Karlsruher Institut für Technologie (KIT), Adenauerring 20a, Geb. 50.41, 76131 Karlsruhe, Deutschland
5 Ständige Senatskommission zur Prüfung gesundheitsschädlicher Arbeitsstoffe, Deutsche Forschungsgemeinschaft, Kennedyallee 40, 53175 Bonn, Deutschland

Abstract

The working group “Analyses in Biological Materials” of the German Senate Commission for the Investigation of Health Hazards of Chemical Compounds in the Work Area (MAK Commission) developed and verified the presented method for the biomonitoring of furan exposure.

This method focuses on the determination of furan in human end-exhaled air. Samples are collected in 20-ml screw-top glass vials (headspace vials) into which the subjects exhale through a PTFE tube. The vials are then sealed using screw caps with PTFE-lined silicone septa. After enrichment of the furan from the gas phase by solid-phase microextraction (SPME), the extract is analysed by gas chromatography. Detection is performed using a triple-quadrupole mass spectrometer with electron-impact ionisation in Multiple Reaction Monitoring (MRM) mode. End-exhaled-air samples spiked with furan are used for external calibration.

The procedure has been comprehensively validated, and the reliability data have been confirmed by replication and verification of the procedure in a second, independent laboratory. Good precision and accuracy data show that the method provides reliable and accurate analytical results. The limit of quantitation of 0.06 ng furan/l end-exhaled air is sufficient to determine occupational exposure as well as exposure to furan after smoking or shortly after coffee consumption.


Keywords

Furan, Biomonitoring, endexspiratorische Ausatemluft, GC-MS/MS, SPME