<?xml version="1.0" encoding="iso-8859-1" standalone="no"?>
<!DOCTYPE GmsArticle SYSTEM "http://www.egms.de/dtd/2.0.34/GmsArticle.dtd">
<GmsArticle xmlns:xlink="http://www.w3.org/1999/xlink">
  <MetaData>
    <Identifier>26dgii24</Identifier>
    <IdentifierDoi>10.3205/26dgii24</IdentifierDoi>
    <IdentifierUrn>urn:nbn:de:0183-26dgii242</IdentifierUrn>
    <ArticleType>Meeting Abstract</ArticleType>
    <TitleGroup>
      <Title language="de">Funktionelle Ergebnisse nach refraktivem Linsenaustausch mit Implantation von Intraokularlinsen mit erweiterter Tiefensch&#228;rfe bei Mini-Monovision</Title>
    </TitleGroup>
    <CreatorList>
      <Creator>
        <PersonNames>
          <Lastname>Khoramnia</Lastname>
          <LastnameHeading>Khoramnia</LastnameHeading>
          <Firstname>Ramin</Firstname>
          <Initials>R</Initials>
        </PersonNames>
        <Address>
          <Affiliation>Dresden</Affiliation>
          <Affiliation>International Vision Correction Research Centre (IVCRC),  Heidelberg</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Naujokaitis</Lastname>
          <LastnameHeading>Naujokaitis</LastnameHeading>
          <Firstname>T.</Firstname>
          <Initials>T</Initials>
        </PersonNames>
        <Address>
          <Affiliation>Dresden</Affiliation>
          <Affiliation>International Vision Correction Research Centre (IVCRC),  Heidelberg</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Kremser</Lastname>
          <LastnameHeading>Kremser</LastnameHeading>
          <Firstname>F.</Firstname>
          <Initials>F</Initials>
        </PersonNames>
        <Address>
          <Affiliation>International Vision Correction Research Centre (IVCRC),  Heidelberg</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Hassel</Lastname>
          <LastnameHeading>Hassel</LastnameHeading>
          <Firstname>O.</Firstname>
          <Initials>O</Initials>
        </PersonNames>
        <Address>
          <Affiliation>International Vision Correction Research Centre (IVCRC),  Heidelberg</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Chychko</Lastname>
          <LastnameHeading>Chychko</LastnameHeading>
          <Firstname>L.</Firstname>
          <Initials>L</Initials>
        </PersonNames>
        <Address>
          <Affiliation>International Vision Correction Research Centre (IVCRC),  Heidelberg</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Vogormian</Lastname>
          <LastnameHeading>Vogormian</LastnameHeading>
          <Firstname>L.</Firstname>
          <Initials>L</Initials>
        </PersonNames>
        <Address>
          <Affiliation>International Vision Correction Research Centre (IVCRC),  Heidelberg</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Negoescu</Lastname>
          <LastnameHeading>Negoescu</LastnameHeading>
          <Firstname>A.</Firstname>
          <Initials>A</Initials>
        </PersonNames>
        <Address>
          <Affiliation>International Vision Correction Research Centre (IVCRC),  Heidelberg</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>&#321;abuz</Lastname>
          <LastnameHeading>&#321;abuz</LastnameHeading>
          <Firstname>G.</Firstname>
          <Initials>G</Initials>
        </PersonNames>
        <Address>
          <Affiliation>International Vision Correction Research Centre (IVCRC),  Heidelberg</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Son</Lastname>
          <LastnameHeading>Son</LastnameHeading>
          <Firstname>H.-S.</Firstname>
          <Initials>HS</Initials>
        </PersonNames>
        <Address>
          <Affiliation>International Vision Correction Research Centre (IVCRC),  Heidelberg</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Auffarth</Lastname>
          <LastnameHeading>Auffarth</LastnameHeading>
          <Firstname>G.U.</Firstname>
          <Initials>GU</Initials>
        </PersonNames>
        <Address>
          <Affiliation>International Vision Correction Research Centre (IVCRC),  Heidelberg</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
    </CreatorList>
    <PublisherList>
      <Publisher>
        <Corporation>
          <Corporatename>German Medical Science GMS Publishing House</Corporatename>
        </Corporation>
        <Address>D&#252;sseldorf</Address>
      </Publisher>
    </PublisherList>
    <SubjectGroup>
      <SubjectheadingDDB>610</SubjectheadingDDB>
    </SubjectGroup>
    <DatePublishedList>
      <DatePublished>20261105</DatePublished>
    </DatePublishedList>
    <Language>germ</Language>
    <License license-type="open-access" xlink:href="http://creativecommons.org/licenses/by/4.0/">
      <AltText language="en">This is an Open Access article distributed under the terms of the Creative Commons Attribution 4.0 License.</AltText>
      <AltText language="de">Dieser Artikel ist ein Open-Access-Artikel und steht unter den Lizenzbedingungen der Creative Commons Attribution 4.0 License (Namensnennung).</AltText>
    </License>
    <SourceGroup>
      <Meeting>
        <MeetingId>M0647</MeetingId>
        <MeetingSequence>24</MeetingSequence>
        <MeetingCorporation>Deutschsprachige Gesellschaft f&#252;r Intraokularlinsen-Implantation, Interventionelle und Refraktive Chirurgie</MeetingCorporation>
        <MeetingName>40. Kongress der Deutschsprachigen Gesellschaft f&#252;r Intraokularlinsen-Implantation, interventionelle und refraktive Chirurgie</MeetingName>
        <MeetingTitle></MeetingTitle>
        <MeetingSession>Presbyopie</MeetingSession>
        <MeetingCity>K&#246;ln</MeetingCity>
        <MeetingDate>
          <DateFrom>20260227</DateFrom>
          <DateTo>20260228</DateTo>
        </MeetingDate>
      </Meeting>
    </SourceGroup>
    <ArticleNo>26dgii24</ArticleNo>
  </MetaData>
  <OrigData>
    <TextBlock name="Text" linked="yes">
      <MainHeadline>Text</MainHeadline><Pgraph><Mark1>Ziel:</Mark1> Ziel dieser Studie war die Evaluierung der funktionellen sowie der patientenberichteten Ergebnisse bei Mini-Monovision nach Implantation einer Intraokularlinse mit erweiterter Tiefensch&#228;rfe (EDoF-IOL) im Rahmen eines beidseitigen, femtosekundenlaserassistierten refraktiven Linsenaustauschs.</Pgraph><Pgraph><Mark1>Methoden:</Mark1> Es handelt sich um eine laufende prospektive, interventionelle Kohortenstudie, in der Patienten im Rahmen eines femtosekundenlaserassistierten refraktiven Linsenaustauschs mit Implantation der Vivity EDoF-IOL (Alcon) behandelt werden. Drei Monate postoperativ wurden der unkorrigierte (UDVA) und korrigierte (CDVA) Fernvisus, der unkorrigierte (UIVA) und distanzkorrigierte (DCIVA) Intermedi&#228;rvisus bei 66 cm sowie der unkorrigierte (UNVA) und distanzkorrigierte (DCNVA) Nahvisus bei 40 cm betimmt und mit den pr&#228;operativen Werten verglichen. Zus&#228;tzlich wurden die postoperative Defokuskurve und die von den Patienten berichtete Brillenunabh&#228;ngigkeit analysiert.</Pgraph><Pgraph><Mark1>Ergebnisse:</Mark1> Bisher wurden 22 Patienten behandelt. Drei Monate nach der Operation (n&#61;7) betrug der mittlere postoperative binokulare UDVA &#8722;0,06&#177;0,05 logMAR und der CDVA &#8722;0,13&#177;0,07 logMAR. Der UIVA lag bei &#8722;0,01&#177;0,04 logMAR und der DCIVA bei &#8722;0,03&#177;0,05 logMAR. Der UNVA betrug 0,11&#177;0,12 logMAR und der DCNVA 0,27&#177;0,12 logMAR. Im Vergleich zum pr&#228;operativen binokularen CDVA (&#8722;0,16&#177;0,04 logMAR) zeigte sich keine statistisch signifikante Ver&#228;nderung (p&#62;0,05), w&#228;hrend alle anderen binokularen Visuswerte signifikant verbessert waren (p&#60;0,05). In der mittleren binokularen Defokuskurve war der Visus im Bereich zwischen &#43;0,5 Dpt. und &#8722;2,0 Dpt. besser als 0,10 logMAR. Die meisten Patienten berichteten &#252;ber vollst&#228;ndige Brillenunabh&#228;ngigkeit bei allt&#228;glichen T&#228;tigkeiten.</Pgraph><Pgraph><Mark1>Schlussfolgerung:</Mark1> Der refraktive Linsenaustausch f&#252;hrte zu einer Verbesserung des unkorrigierten Visus in der Ferne, im Intermedi&#228;r- und Nahbereich, ohne den korrigierten Fernvisus zu beeintr&#228;chtigen. Die Patienten erreichten ein hohes Ma&#223; an Brillenunabh&#228;ngigkeit.</Pgraph></TextBlock>
    <Media>
      <Tables>
        <NoOfTables>0</NoOfTables>
      </Tables>
      <Figures>
        <NoOfPictures>0</NoOfPictures>
      </Figures>
      <InlineFigures>
        <NoOfPictures>0</NoOfPictures>
      </InlineFigures>
      <Attachments>
        <NoOfAttachments>0</NoOfAttachments>
      </Attachments>
    </Media>
  </OrigData>
</GmsArticle>