<?xml version="1.0" encoding="iso-8859-1" standalone="no"?>
<!DOCTYPE GmsArticle SYSTEM "http://www.egms.de/dtd/2.0.34/GmsArticle.dtd">
<GmsArticle xmlns:xlink="http://www.w3.org/1999/xlink">
  <MetaData>
    <Identifier>25dgii38</Identifier>
    <IdentifierDoi>10.3205/25dgii38</IdentifierDoi>
    <IdentifierUrn>urn:nbn:de:0183-25dgii382</IdentifierUrn>
    <ArticleType>Meeting Abstract</ArticleType>
    <TitleGroup>
      <Title language="de">Bewertung der Leseleistung mittels Salzburg Reading Desk nach Implantation einer diffraktiven trifokalen Intraokularlinse beim refraktiven Linsenaustausch</Title>
    </TitleGroup>
    <CreatorList>
      <Creator>
        <PersonNames>
          <Lastname>Naujokaitis</Lastname>
          <LastnameHeading>Naujokaitis</LastnameHeading>
          <Firstname>Tadas</Firstname>
          <Initials>T</Initials>
        </PersonNames>
        <Address>
          <Affiliation>International Vision Correction Research Centre (IVCRC), Universit&#228;ts-Augenklinik Heidelberg</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Auffarth</Lastname>
          <LastnameHeading>Auffarth</LastnameHeading>
          <Firstname>G.U.</Firstname>
          <Initials>GU</Initials>
        </PersonNames>
        <Address>
          <Affiliation>International Vision Correction Research Centre (IVCRC), Universit&#228;ts-Augenklinik Heidelberg</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Baur</Lastname>
          <LastnameHeading>Baur</LastnameHeading>
          <Firstname>I.D.</Firstname>
          <Initials>ID</Initials>
        </PersonNames>
        <Address>
          <Affiliation>International Vision Correction Research Centre (IVCRC), Universit&#228;ts-Augenklinik Heidelberg</Affiliation>
          <Affiliation>Augsburg</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Hassel</Lastname>
          <LastnameHeading>Hassel</LastnameHeading>
          <Firstname>O.</Firstname>
          <Initials>O</Initials>
        </PersonNames>
        <Address>
          <Affiliation>International Vision Correction Research Centre (IVCRC), Universit&#228;ts-Augenklinik Heidelberg</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Henningsen</Lastname>
          <LastnameHeading>Henningsen</LastnameHeading>
          <Firstname>N.</Firstname>
          <Initials>N</Initials>
        </PersonNames>
        <Address>
          <Affiliation>International Vision Correction Research Centre (IVCRC), Universit&#228;ts-Augenklinik Heidelberg</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Reitemeyer</Lastname>
          <LastnameHeading>Reitemeyer</LastnameHeading>
          <Firstname>E.</Firstname>
          <Initials>E</Initials>
        </PersonNames>
        <Address>
          <Affiliation>International Vision Correction Research Centre (IVCRC), Universit&#228;ts-Augenklinik Heidelberg</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Chychko</Lastname>
          <LastnameHeading>Chychko</LastnameHeading>
          <Firstname>L.</Firstname>
          <Initials>L</Initials>
        </PersonNames>
        <Address>
          <Affiliation>International Vision Correction Research Centre (IVCRC), Universit&#228;ts-Augenklinik Heidelberg</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>&#321;abuz</Lastname>
          <LastnameHeading>&#321;abuz</LastnameHeading>
          <Firstname>G.</Firstname>
          <Initials>G</Initials>
        </PersonNames>
        <Address>
          <Affiliation>International Vision Correction Research Centre (IVCRC), Universit&#228;ts-Augenklinik Heidelberg</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Khoramnia</Lastname>
          <LastnameHeading>Khoramnia</LastnameHeading>
          <Firstname>R.</Firstname>
          <Initials>R</Initials>
        </PersonNames>
        <Address>
          <Affiliation>International Vision Correction Research Centre (IVCRC), Universit&#228;ts-Augenklinik Heidelberg</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
    </CreatorList>
    <PublisherList>
      <Publisher>
        <Corporation>
          <Corporatename>German Medical Science GMS Publishing House</Corporatename>
        </Corporation>
        <Address>D&#252;sseldorf</Address>
      </Publisher>
    </PublisherList>
    <SubjectGroup>
      <SubjectheadingDDB>610</SubjectheadingDDB>
    </SubjectGroup>
    <DatePublishedList>
      <DatePublished>20250603</DatePublished>
    </DatePublishedList>
    <Language>germ</Language>
    <License license-type="open-access" xlink:href="http://creativecommons.org/licenses/by/4.0/">
      <AltText language="en">This is an Open Access article distributed under the terms of the Creative Commons Attribution 4.0 License.</AltText>
      <AltText language="de">Dieser Artikel ist ein Open-Access-Artikel und steht unter den Lizenzbedingungen der Creative Commons Attribution 4.0 License (Namensnennung).</AltText>
    </License>
    <SourceGroup>
      <Meeting>
        <MeetingId>M0620</MeetingId>
        <MeetingSequence>38</MeetingSequence>
        <MeetingCorporation>Deutschsprachige Gesellschaft f&#252;r Intraokularlinsen-Implantation, Interventionelle und Refraktive Chirurgie</MeetingCorporation>
        <MeetingName>39. Kongress der Deutschsprachigen Gesellschaft f&#252;r Intraokularlinsen-Implantation, interventionelle und refraktive Chirurgie</MeetingName>
        <MeetingTitle></MeetingTitle>
        <MeetingSession>Presbyopie und IOL</MeetingSession>
        <MeetingCity>Erlangen</MeetingCity>
        <MeetingDate>
          <DateFrom>20250213</DateFrom>
          <DateTo>20250215</DateTo>
        </MeetingDate>
      </Meeting>
    </SourceGroup>
    <ArticleNo>25dgii38</ArticleNo>
  </MetaData>
  <OrigData>
    <TextBlock name="Text" linked="yes">
      <MainHeadline>Text</MainHeadline><Pgraph><Mark1>Fragestellung:</Mark1> Bewertung der Leseleistung mittels Salzburg Reading Desk (SRD Vision) nach binokularem refraktivem Linsenaustausch und Implantation der Clareon PanOptix IOL (Alcon). Die untersuchte IOL besteht aus einem Glistening-freien hydrophoben Acrylat und ist der Nachfolger der AcrySof IQ PanOptix IOL.</Pgraph><Pgraph><Mark1>Methoden:</Mark1> In dieser prospektiven, interventionellen Studie wurde bei 54 Augen von 27 Patienten ein beidseitiger Femtosekundenlaser-assistierter refraktiver Linsenaustausch mit Implantation der Clareon PanOptix IOL durchgef&#252;hrt. Die Leseleistung wurde pr&#228;operativ und 6 Monate postoperativ mittels Salzburg Reading Desk bewertet. Der monokulare und binokulare Lesevisus, mit und ohne Fernkorrektur, sowie die Lesegeschwindigkeit wurden bei den Entfernungen von 40 cm und 60 cm sowie bei den subjektiv bevorzugten Entfernungen bestimmt. Die Mittelwerte und Standardabweichungen sind angegeben.</Pgraph><Pgraph><Mark1>Ergebnisse:</Mark1> Das mittlere Alter der Patienten (&#177; Standardabweichung) betrug 55&#177;5 Jahre. Vor der Operation lag der mittlere binokulare unkorrigierte Lesevisus bei 0,53&#177;0,22 logMAR in der N&#228;he (40 cm) und bei 0,53&#177;0,22 logMAR im Intermedi&#228;rbereich (60 cm). Postoperativ betrug der binokulare unkorrigierte Lesevisus 0,05&#177;0,08 logMAR bei der festgelegten Nahdistanz (40 cm) und 0,05&#177;0,09 logMAR bei der subjektiv bevorzugten Nahdistanz (38,8&#177;2,5 cm). Bei der festgelegten Entfernung von 60 cm betrug der postoperative unkorrigierte Lesevisus 0,09&#177;0,10 logMAR. Die bevorzugte mittlere Entfernung betrug 57,6&#177;4,1 cm, bei welcher ein unkorrigierter Lesevisus von 0,07&#177;0,10 logMAR bestimmt wurde. </Pgraph><Pgraph><Mark1>Schlussfolgerungen:</Mark1> Der unkorrigierte Lesevisus im Intermedi&#228;r- und Nahbereich verbesserte sich nach der bilateralen Implantation der diffraktiven trifokalen IOL. Die Lesefunktion war f&#252;r die festgelegten und subjektiv bevorzugten Entfernungen vergleichbar.</Pgraph></TextBlock>
    <Media>
      <Tables>
        <NoOfTables>0</NoOfTables>
      </Tables>
      <Figures>
        <NoOfPictures>0</NoOfPictures>
      </Figures>
      <InlineFigures>
        <NoOfPictures>0</NoOfPictures>
      </InlineFigures>
      <Attachments>
        <NoOfAttachments>0</NoOfAttachments>
      </Attachments>
    </Media>
  </OrigData>
</GmsArticle>